93 IDI over fueling?

Betty White

Registered User
Joined
Jul 11, 2024
Posts
6
Reaction score
1
Location
Indiana
I changed my rear fuel tank because of algae.Truck runs great.It intermittently now will start rattling and blowing white smoke and fuel out the exhaust,then back to normal at highway speed.I don't think I hooked up lines backwards.And they are both 5/16 because I think they have been changed.Any help where to start?93 7.3 idi
 

Finn

Registered User
Joined
Apr 4, 2008
Posts
15
Reaction score
6
Location
naperville Il, Dollarbay
Check the oil level on the dipstick. Sounds like an overfilled crankcase / pan, resulting in windage driven oil carryover through the CDR valve into the intake manifold.

If the pan is overfilled, the pump shaft seal is likely leaking. Later engines had a weep hole to keep fuel from overfilling the crankcase.
 

Rdnck84_03

Full Access Member
Joined
Jan 15, 2019
Posts
1,368
Reaction score
1,499
Location
Kansas
If the crankcase is over full and you are still running the mechanical lift pump, I would would start there before thinking the IP.

Oil diluted with fuel is normally how mechanical pumps go, gas an diesel.

James
 

Black dawg

Registered User
Joined
Jan 9, 2006
Posts
4,462
Reaction score
1,041
Location
sw mt
The next time I need to try and talk over someone's head or just confuse them I'm gonna' talk about "windage driven oil carryover". :Thumbs Up
Lol.
Guy has some pretty interesting posts, like maybe he was involved in development or testing of these engines. Would be interesting to here what he has to say if that is the case.
 

Forum statistics

Threads
92,929
Posts
1,155,105
Members
26,430
Latest member
Brownlee5212

Members online

No members online now.