Search results

  1. D

    How do I charge a 24 volt battery

    They use 24v batteries on aircraft.
  2. D

    Loads of information here.

    Thanks I went to this site signed up and am still looking at it. I did'nt know the library had this service.
  3. D

    starters.

    I have bought three of these starters two for the idi and one for my backhoe. I thought the backhoe was getting ready for a rebuild. now I am pissed if it takes more than 3 seconds to pop over. hell of a difference I have a lot more time on the backhoe starter as the idi still needs the c6...
  4. D

    Can I ground both a 12V and a 24V alternator to the same ground

    "One thing driving me nuts is I don't know what kinda gear pump that is. Its got a plate on it with some numbers but thats about it for identification. Got it for $20 out of a surplus store. Works OK but I think its pretty worn out. And you were right on about how long it takes to fill that...
  5. D

    Can I ground both a 12V and a 24V alternator to the same ground

    I think this application is a little different than the military I would say 90% of load is 12v so to draw that much off the 12v tap would be hard on both batteries.
  6. D

    Can I ground both a 12V and a 24V alternator to the same ground

    how large are your pumps ? hp? the wiring diagram will give you 12v and 24 v but no way to charge all batteries with 12v and still have 24v available. depending on your current draw with the pumps: maybe a 12v to 110vac inverter running into a 24v battery charger then into a 24v battery bank .
  7. D

    Help understanding a points ignition system

    an old gm with a hei was a good improvement but this guy was working on the dwell meter for an old dodge. which could be probably be changed out to the chrysler pointless ignition. and would be a good improvement.
  8. D

    Dyoung14, Please read. I am sorry.

    Hey usps is no better in kicking things around. I always insure something for 2-3 hundred and it is surprising how those things don't get kicked around. the post office has all your information not like your a terrorist or anything. and if it's insured they have to explain why. but you have to...
  9. D

    T-Stat and Zero PSI cap for waterless coolant

    zero psi cap? take a normal cap remove small rubber seal in very center. Actually about size of silver dollar. now your system will not pressurize but will still expand to expansion tank.
  10. D

    dana 44 axle seals replacement

    Yeah they are a sob. I have put a couple of them in and screwed up more. the trick is you have to press sideways. I did it wood and crowbars to start it. once it is partially installed I tapped the seal in from the tube on the other side of the axle. lots of coordination. one guy taps and the...
  11. D

    Questions specifically related to converting my distributor

    find a junker chrylser went to pointless dist. in 75 just change dist and wire up it still uses the same coil and ballast resistor I have a 73 dodge book and way too many old chyslers. three 75 cordobas. pm me and I will post what I can help you with. the books I have should give me wire...
  12. D

    Help understanding a points ignition system

    Most of the point ignition's were measured with feeler guage's so around .016 thousand's. the early gm's used a dwell meter but you had to have a way to adjust the points while turning over hence it had a little window to open and a allen head adjustment to set dwell. but it was still a more or...
  13. D

    IDI brings home a new international

    remember these engines time on #8 plug. check if the air cleaner bolt is threaded into center of carb or held by a crossover bar over rhe throat of the carb. My point the center bolt for the air cleaner would be tightened down too tight and warp the top half of the carb. easy fix take off top...
  14. D

    I have to vent!

    I did a google search on what temp does #2ulsd gel at. and it was interesting it appears the #1 diesel is in low supply for the winter blend and the #2 gel's above 0 degrees. Maybe an additive would be a thing to try. I have froze up my dozer twice in the past ten years and almost cry when my ip...
  15. D

    Glow plugs drivin me crazy

    The relay works, if i touch a ground to were the white wire is hooked then you can here it click, the controller was working great on my 86 the other day, there is no way it went bad in a day __________________ ~David~ this is the ground wire. ground it.
  16. D

    1989 f250 C-6 glowplug problem

    I see that it has melted and the PO has spliced some wires were the glow plug wires melted out of it __________________ ~David~ I would look there first. it might be pretty obvious or you might need a multimeter to check the connections.
  17. D

    high torque starter

    high torque starter origin The starters work great I have two of them . They come from china. Who did you think made them?
  18. D

    transmission swap from85 6.9 t088 7.3

    Thank you thank you When I bought this partstruck I thought I had just what I wanted. Then I was worried about the flywheel working between the two different size motors.Then it was this dual mass flywheel or clutch thing. I am so relivied that this thing so be able to be swapped out without...
  19. D

    transmission swap from85 6.9 t088 7.3

    I just bought a 1985 6.9with a 4-speed manual and would like to know if I can bolt it up to my 88 7.3 with the automatic my c-6 is toast and I am concerned about using the 6.9 flywheel om the 7.3. Will it bolt up and will there be any issues with balance between the 6.9 and the 7.3. I live up...
Top