  1. HammerDown

    Fuel Filter Heater 7.3 Info?

    Hey fellas, anyone know the sizes of the two 0-rings that are in the fuel heater head? I have the Napa numbers but they only come in 10 packs and the size isn't listed on the packs. No local International dealers around me anymore so, looking to maybe get them up at my local hardware store...
  2. HammerDown

    Champion radiators SUCK!!!!

    As per my recent research, pretty sure that now currently comes with PLASTIC tanks.
  3. HammerDown

    Champion radiators SUCK!!!!

    I too keep ALL receipts! I'm not dealing with mail-order items that important and LARGE pulse the shipping cost, then it's their opinion as to warranty or not and the down time so, and even though a plastic tank will eventually fail too and when it does, Auto Zone or Advance will exchange it...
  4. HammerDown

    Fuel Filter Heater 7.3 Info?

    Thanks for the detailed reply...but I'm an oe kinda guy so I want to attempt to replace those two o-rings. On YouTube I have located a video and the fella states Napa has or can get the needed o-rings and the part numbers are BK727-2014 & BK727-2016 Of course when I call Napa tomorrow they...
  5. HammerDown

    Champion radiators SUCK!!!!

    Coincidence this topic came up as, my old brass-copper radiator is weeping but not enough to leave a mark. To have it repaired/recored is $600 = no way! I thought about Champion but no one local sells it so when it does fail I can't simply return it to a local store for the limited lifetime...
  6. HammerDown

    Fuel Filter Heater 7.3 Info?

    He fellas, it appears the heater plug atop my filter housing is beginning to weep just a bit. Since new (1988) I have never removed the electrical black plastic boot/cover and if I 'now' try to gently get under it, it feels like it will break into pieces. Does this black cover pop off as it...
  7. HammerDown

    Dammit Need A Radiator!

    Well, with my Vette many-many years ago it did develop a leak at the top hose connection into the tank. I pulled it, cleaned the area and braised in some solder with a torch...it held for a very long time but then developed a leak between the the two cores...how does one fix that? With my...
  8. HammerDown

    Dammit Need A Radiator!

    Thanks for the champion info and link...also knowing my old brass-copper is worth a few bucks at the scrap yard! Not working for 6 years (health issues) plus house insurance and the school bill sitting on the table makes for bad timing for a weepy radiator replacement. BTW...sent a question...
  9. HammerDown

    Dammit Need A Radiator!

    I was wondering why the pic looked so different...thought maybe it was just stretched. However below it does specify it is for my year make model and engine? "This product is a fit for your: 1988 Ford Truck F250 3/4 ton P/U 4WD 7.3L Diesel 8cyl Part Number: B1166 Alternate Part Number: CU1166"
  10. HammerDown

    Dammit Need A Radiator!

    Well, it's been in use a loooooong time but it appears the top tank has a slight leak. Finances are tight...looking for the least expensive options. Anyone use these options from Auto zone, one is copper the other aluminum...
  11. HammerDown

    At TImes A Noist Injector???

    That's just it, there's no reason when or why...hot or cold temps, damn thing sounds like a typewriter, I can run it for an hour and it's tapping away then it may go dead quiet. Restart it and it's quiet, then later that day it's hammering. But a heavy dose of TCW3 helps muffle the noise, this...
  12. HammerDown

    At TImes A Noist Injector???

    Are you referring to the return lines, like maybe if the inside rubber returns lines are breaking down...but doesn't the return line send unused fuel back to the fuel tank then, it's re-filtered once it hits the main fuel filter?
  13. HammerDown

    At TImes A Noist Injector???

    Ok, so back when I got the 'new' Delphi BB's I borrowed a pop-tester from a friend...he's 70 miles away. I never thought to listen to each one with a stethoscope which I do have. "could metal have gotten in one?" Well, I don't know how but again why would one injector 'at times' be tapping and...
  14. HammerDown

    At TImes A Noist Injector???

    Wow, you remember about my brother, well, May 17'th 2013 at 8am I received the call by brothers dismembered, disemboweled rotting remains were in two Rubbermaid containers since she murdered him August 3'rd 2007. I knew she murdered him but I had no idea how horrific the reality would be. Back...
  15. HammerDown

    At TImes A Noist Injector???

    But again, I personally tested each injector...and tested very good.
  16. HammerDown

    At TImes A Noist Injector???

    At TImes A Noisy Injector??? Question, why at times would an injector become noisy...it almost sounds like a lifter-tap but I know it's an injector because when I add TCW3 to the fuel it gets quiet. And, at times even without the TCW3 added it will be quiet. I would think either an injector...
  17. HammerDown

    7.3 IDI Block Heater Cord Question

    BTW...just wanted to mention...how my OE heater is 'clocked' into the block the Napa plug below would exit the cord facing the front of the engine. If the Napa/Kats plug has a snug fit into the socket, I believe the below would have worked perfectly...
  18. HammerDown

    7.3 IDI Block Heater Cord Question

    Removed the old cord and fixed it up reeeeeal nice! Got me some 'Liquid Electrical Tap' gooped it on and then used some heat-shrink...BAM...done deal ;Sweet Now, I'm sure if I use it the o-ring will start leaking or the heating element with burn out...my luck ;Really
  19. HammerDown

    7.3 IDI Block Heater Cord Question

    Thanks for the feedback fellas...I did notice the plug to wire exit and was wondering 'if' that would be an issue. On mine, where the wire exits the plug the insulating cover is cracked exposing the bare wire...so that's why I need to replace it. BTW...good to know I can remove the plug...
  20. HammerDown

    7.3 IDI Block Heater Cord Question

    Looks close but??? I'll recall Kat's tomorrow hopefully a tech-rep can answer application fitment. Napa can also get the Kat's cord, but they have no idea if it will fit. http://www.napaonline.com/Catalog/CatalogItemDetail.aspx/Engine-Heater-Power-Cord-KAT/_/R-KAT28400_0477754238 Looks like...
  21. HammerDown

    7.3 IDI Block Heater Cord Question

    Anyone know if the below Kat's cord will work for a 7.3 IDI ? I know "Zerostat" has a replacement cord, but it's twice as much. Also, I'm hoping I can replace the 'cord' without pulling the starter? I tried to call Kat's...their closed today because of a dusting of snow (located in Tennessee)...
  22. HammerDown

    Block heater

    So, is the cord replaceable and if so where could it be purchased??? EDIT...I see them on eBay, I need one, checking Rock Auto
  23. HammerDown

    First Time in 27 Years...

    Update... this morning was zero with temps windchill -10 degrees + Didn't use the block heater (never really do) Long GP burn, turn the key...engine went around 2-3 times and...BAM...it fired so hard I though it was coming through the hood! ;Sweet to Power-Service in the White Bottle!
  24. HammerDown

    Block heater

    Unless you can drain the engine block (I couldn't) not a fun job...especially if doing it in the freezing temps. I had to drain the rad and then pulled the lower rad hose...I still got a wet arm and face (sucks) No way around it, the starter has to come out, and that's not too...
  25. HammerDown

    First Time in 27 Years...

    This tank of fuel was from a Citgo in Williamstown NJ...filled both tanks because it was cheaper then here on the Pa side. Anyhow, the truck fired fight off this morning, it lite so quick I thought it was going to bust away from the engine mounts. The engine REALLY likes this double dose of...