97 OBS powerstroke, leaking at the "quick disconnect" fuel line fittings below the PS pump on the drivers side. Haven't investigated further but wondering if I can replace with rubber diesel rated fuel line and clamps?
 

79jasper

Chickenhawk
Joined
Oct 13, 2012
Posts
17,367
Reaction score
1,930
Location
Collinsville, Oklahoma
I've heard of people doing that.
The lines can be bought as a set, around $300 iirc. (Too much imo)
Orings can be replaced as well, but that's a pita.
Runner line and some heat shield would be my vote.

Sent from my SM-N960U using Tapatalk
 

Randy Bush

Full Access Member
Joined
Jan 2, 2019
Posts
708
Reaction score
453
Location
Great Falls, Mt
Fairly easy to just replace the fittings. Think it cost me around $50 for the fitting when I did mine.
 

Skidtech

Full Access Member
Joined
May 27, 2018
Posts
90
Reaction score
17
Location
Idaho
If you take the old one to a tractor shop where they make hydraulic hoses you should be able to get a custom braided steel replacement pretty cheap.

Sent from my LG-H700 using Tapatalk
 

Garbage_Mechan

Garbage Mechanic
Joined
Jun 9, 2008
Posts
989
Reaction score
492
Location
Central Cal Foothills
If you have a stock fuel system the supply side is under suction and the return side has just the restriction of flow in the lines to build pressure. The spring lock couplings have one brown viton and one blue flourosilicone oring. They are replaceable with an oring pick and patience. Viton orings will be ok. I would be suprised if the orings are leaking, blue flourosilicone is nearly a lifetime oring.
 

Garbage_Mechan

Garbage Mechanic
Joined
Jun 9, 2008
Posts
989
Reaction score
492
Location
Central Cal Foothills
Another interesting problem is that the steel tubing the push on couplers attach to is 5/16 on one side and 3/8 on the other. On the supply line. The return is 5/16 both sides. So if it is the supply hose itself you can either just clamp the crap out of it or use the replacement plastic couplers available at auto parts. They should have a 5/16 by 3/8 hose and 3/8 by 3/8 hose. Use diesel rated hose and clamps. I would heat wrap it due to the proximity to the exhaust.
 

greenskeeper

Full Access Member
Joined
Mar 16, 2013
Posts
995
Reaction score
202
Location
PA
Driving with the leak for now...really only shows up after a highway run from those fittings....few drips once parked.
 